72 research outputs found

    Advanced modelling of the Planck-LFI radiometers

    Get PDF
    The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.Comment: 21 pages, 15 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins

    Planck-LFI radiometers' spectral response

    Get PDF
    The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.Comment: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins

    Thermal susceptibility of the Planck-LFI receivers

    Get PDF
    This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.Comment: This is an author-created, un-copyedited version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T1201

    The linearity response of the Planck-LFI flight model receivers

    Get PDF
    In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.Comment: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12011

    Low noise amplifiers in InP technology for pseudo correlating millimeter wave radiometer

    Get PDF
    This decade will be very important for cosmology due to several missions to measure the cosmic microwave background radiation. These measurements require highly sensitive radiometers operating over a very wide frequency spectrum. The millimeter wave radiometers are best developed as pseudo correlating radiometers due to the inherent stability and high sensitivity of this instrument, To miniaturize the size and power consumption of these radiometers we have developed the critical low noise amplifier and phase switch MMICs using high-performance InP technologies. The low noise amplifiers achieved record 2.3 dB noise figure over the 60-80 GHz frequency band at room temperature and less than 25 K noise temperature at 20 K ambient temperature. These MMICs form the building blocks for 70 GHz highly sensitive correlating radiometers, that are needed e.g. in the ESA Planck mission

    Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    Get PDF
    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysic

    Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

    Get PDF
    We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f1/f stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.Comment: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010

    Drinking in transition: trends in alcohol consumption in Russia 1994-2004

    Get PDF
    BACKGROUND: Heavy alcohol consumption is widespread in Russia, but studying changes in drinking during the transition from Communism has been hampered previously by the lack of frequent data. This paper uses 1-2 yearly panel data, comparing consumption trends with the rapid concurrent changes in economic variables (notably around the "Rouble crisis", shortly preceding the 1998 survey round), and mortality. METHODS: Data were from 9 rounds (1994-2004) of the 38-centre Russia Longitudinal Monitoring Survey. Respondents aged over 18 were included (>7,000 per round). Trends were measured in alcohol frequency, quantity per occasion (by beverage type) and 2 measures of potentially hazardous consumption: (i) frequent, heavy spirit drinking (≄80 g per occasion of vodka or samogon and >weekly) (ii) consuming samogon (cheap home-distilled spirit). Trends in consumption, mean household income and national mortality rates (in the same and subsequent 2 years) were compared. Finally, in a subsample of individual male respondents present in both the 1996 and 1998 rounds (before and after the financial crash), determinants of changes in harmful consumption were studied using logistic regression. RESULTS: Frequent, heavy spirit drinking (>80 g each time, ≄weekly) was widespread amongst men (12-17%) throughout, especially in the middle aged and less educated; with the exception of a significant, temporary drop to 10% in 1998. From 1996-2000, samogon drinking more than doubled, from 6% to 16% of males; despite a decline, levels were significantly higher in 2004 than 1996 in both sexes. Amongst women, frequent heavy spirit drinking rose non-significantly to more than 1% during the study. Heavy frequent male drinking and mortality in the same year were correlated in lower educated males, but not in women. Individual logistic regression in a male subsample showed that between 1996 and1998, those who lost their employment were more likely to cease frequent, heavy drinking; however, men who commenced drinking samogon in 1998 were more likely to be rural residents, materially poor, very heavy drinkers or pessimistic about their finances. These changes were unexplained by losses to follow-up. CONCLUSIONS: Sudden economic decline in late 1990s Russia was associated with a sharp, temporary fall in heavy drinking, and a gradual and persistent increase in home distilled spirit consumption, with the latter more common amongst disadvantaged groups. The correlation between heavy drinking and national mortality in lower educated men is interesting, but the timing of RLMS surveys late in the calendar year, and the absence of any correlation between drinking and the subsequent year's mortality, makes these data hard to interpret. Potential study limitations include difficulty in measuring multiple beverages consumed per occasion, and not specifically recording "surrogate" (non-beverage) alcohols
    • 

    corecore